T1 - Cancers not detected in one-view breast tomosynthesis screening—characteristics and reasons for non-detection
AU - Johnson, Kristin
AU - Ikeda, Debra M.
AU - Andersson, Ingvar
AU - Zackrisson, Sophia
PY - 2024
Y1 - 2024
N2 - Objectives: Limited understanding exists regarding non-detected cancers in digital breast tomosynthesis (DBT) screening. This study aims to classify non-detected cancers into true or false negatives, compare them with true positives, and analyze reasons for non-detection. Materials and methods: Conducted between 2010 and 2015, the prospective single-center Malmö Breast Tomosynthesis Screening Trial (MBTST) compared one-view DBT and two-view digital mammography (DM). Cancers not detected by DBT, i.e., interval cancers, those detected in the next screening round, and those only identified by DM, underwent a retrospective informed review by in total four breast radiologists. Reviewers classified cancers into true negative, false negative, or non-visible based on both DBT and DM findings and assessed radiographic appearances at screening and diagnosis, breast density, and reasons for non-detection. Statistics included the Pearson X2 test. Results: In total, 89 cancers were not detected with DBT in the MBTST; eight cancers were solely in the DM reading mode, 59 during subsequent DM screening rounds, and 22 interval cancers. The proportion of cancers classified as false negative was 25% (22/89) based on DBT, compared with 18% (14/81) based on DM screening. The primary reason for false negatives was normal-appearing density, 50% (11/22). False negatives exhibited lower rates of high breast density, 36% (8/22), compared with true positives, 61% (78/129), p = 0.04, and spiculated densities were less frequent in false negatives, 41% (9/22) compared with true positives, 68% (88/129), p = 0.01. Conclusion: False negatives in one-view DBT screening commonly presented with spiculated features, but less frequently than true positives, and were missed or misinterpreted due to benign appearances. Key Points: Question Cancers not detected in digital breast tomosynthesis screening, including false negatives, remain partly unexplored. Findings The most common reason behind false-negative cancers in a large screening trial was a normal-appearing density. Clinical relevance Recognizing the factors contributing to false negative findings in digital breast tomosynthesis screening is essential to further improve cancer detection.
AB - Objectives: Limited understanding exists regarding non-detected cancers in digital breast tomosynthesis (DBT) screening. This study aims to classify non-detected cancers into true or false negatives, compare them with true positives, and analyze reasons for non-detection. Materials and methods: Conducted between 2010 and 2015, the prospective single-center Malmö Breast Tomosynthesis Screening Trial (MBTST) compared one-view DBT and two-view digital mammography (DM). Cancers not detected by DBT, i.e., interval cancers, those detected in the next screening round, and those only identified by DM, underwent a retrospective informed review by in total four breast radiologists. Reviewers classified cancers into true negative, false negative, or non-visible based on both DBT and DM findings and assessed radiographic appearances at screening and diagnosis, breast density, and reasons for non-detection. Statistics included the Pearson X2 test. Results: In total, 89 cancers were not detected with DBT in the MBTST; eight cancers were solely in the DM reading mode, 59 during subsequent DM screening rounds, and 22 interval cancers. The proportion of cancers classified as false negative was 25% (22/89) based on DBT, compared with 18% (14/81) based on DM screening. The primary reason for false negatives was normal-appearing density, 50% (11/22). False negatives exhibited lower rates of high breast density, 36% (8/22), compared with true positives, 61% (78/129), p = 0.04, and spiculated densities were less frequent in false negatives, 41% (9/22) compared with true positives, 68% (88/129), p = 0.01. Conclusion: False negatives in one-view DBT screening commonly presented with spiculated features, but less frequently than true positives, and were missed or misinterpreted due to benign appearances. Key Points: Question Cancers not detected in digital breast tomosynthesis screening, including false negatives, remain partly unexplored. Findings The most common reason behind false-negative cancers in a large screening trial was a normal-appearing density. Clinical relevance Recognizing the factors contributing to false negative findings in digital breast tomosynthesis screening is essential to further improve cancer detection.
KW - Adults
KW - Breast
KW - Mammography
KW - Screening
KW - Tomosynthesis
U2 - 10.1007/s00330-024-11278-2
DO - 10.1007/s00330-024-11278-2
M3 - Article
C2 - 39706921
AN - SCOPUS:85212688917
SN - 0938-7994
JO - European Radiology
JF - European Radiology
ER -