Center experience and other determinants of patient radiation exposure during prostatic artery embolization: a retrospective study in three Scandinavian centers

Petra Svarc, Thijs Hagen, Hanne Waltenburg, Christian Andersson, Mats Bläckberg, Eduard Baco, Mikkel Taudorf, Martin Andreas Røder, Hans Lindgren, Nils Einar Kløw, Lars Birger Lönn

Forskningsoutput: TidskriftsbidragArtikel i vetenskaplig tidskriftPeer review

Sammanfattning

Objectives: To evaluate the effects of center experience and a variety of patient- and procedure-related factors on patient radiation exposure during prostatic artery embolization (PAE) in three Scandinavian centers with different PAE protocols and levels of experience. Understanding factors that influence radiation exposure is crucial in effective patient selection and procedural planning. Methods: Data were collected retrospectively for 352 consecutive PAE procedures from January 2015 to June 2020 at the three centers. Dose area product (DAP (Gy·cm2)) was selected as the primary outcome measure of radiation exposure. Multiple patient- and procedure-related explanatory variables were collected and correlated with the outcome variable. A multiple linear regression model was built to determine significant predictors of increased or decreased radiation exposure as reflected by DAP. Results: There was considerable variation in DAP between the centers. Intended unilateral PAE (p = 0.03) and each 10 additional patients treated (p = 0.02) were significant predictors of decreased DAP. Conversely, increased patient body mass index (BMI, p < 0.001), fluoroscopy time (p < 0.001), and number of digital subtraction angiography (DSA) acquisitions (p < 0.001) were significant predictors of increased DAP. Conclusions: To minimize patient radiation exposure during PAE radiologists may, in collaboration with clinicians, consider unilateral embolization, pre-interventional CTA for procedure planning, using predominantly anteroposterior (AP) projections, and limiting the use of cone-beam CT (CBCT) and fluoroscopy. Key Points: • Growing center experience and intended unilateral embolization decrease patient radiation exposure during prostatic artery embolization. • Patient BMI, fluoroscopy time, and number of DSA acquisitions are associated with increased DAP during procedures. • Large variation in radiation exposure between the centers may reflect the use of CTA before and CBCT during the procedure.

Originalspråkengelska
Sidor (från-till)2404-2413
TidskriftEuropean Radiology
Volym32
Nummer4
Tidigt onlinedatum2021
DOI
StatusPublished - 2022

Bibliografisk information

Publisher Copyright:
© 2021, European Society of Radiology.

Ämnesklassifikation (UKÄ)

  • Radiologi och bildbehandling

Fingeravtryck

Utforska forskningsämnen för ”Center experience and other determinants of patient radiation exposure during prostatic artery embolization: a retrospective study in three Scandinavian centers”. Tillsammans bildar de ett unikt fingeravtryck.

Citera det här