TY - JOUR
T1 - Development and application of an analytical protocol for evaluation of treatment processes for landfill leachates. I. Development of an analytical protocol for handling organic compounds in complex leachate samples
AU - Bergström, Staffan
AU - Svensson, Britt-Marie
AU - Martensson, Lennart
AU - Mathiasson, Lennart
N1 - The information about affiliations in this record was updated in December 2015.
The record was previously connected to the following departments: Analytical Chemistry (S/LTH) (011001004)
PY - 2007
Y1 - 2007
N2 - A strategy is presented for evaluation of treatment procedures for landfill leachate with emphasis on organic pollutants. An analytical scheme, the LAQUA protocol, was developed as a guide for the analytical work. The protocol includes organic as well as metals,. inorganic ions, water-quality parameters, and toxicity. The proposed strategy considers the behaviour of both polar and non-polar organic substances at trace levels. For polar substances, phenols were chosen as markers and determined with an automated supported liquid membrane extraction device, coupled on-line to HPLC with a diode-array detector. For non-polar substances, PCBs and 10 unidentified compounds were chosen as markers and analysed by solid-phase extraction combined with supercritical fluid extraction with GC analysis. The chosen measurement strategy, based on the use of marker substances, difference measurements, and versatile data-handling procedures, provided essential information about complex systems at relatively low cost.
AB - A strategy is presented for evaluation of treatment procedures for landfill leachate with emphasis on organic pollutants. An analytical scheme, the LAQUA protocol, was developed as a guide for the analytical work. The protocol includes organic as well as metals,. inorganic ions, water-quality parameters, and toxicity. The proposed strategy considers the behaviour of both polar and non-polar organic substances at trace levels. For polar substances, phenols were chosen as markers and determined with an automated supported liquid membrane extraction device, coupled on-line to HPLC with a diode-array detector. For non-polar substances, PCBs and 10 unidentified compounds were chosen as markers and analysed by solid-phase extraction combined with supercritical fluid extraction with GC analysis. The chosen measurement strategy, based on the use of marker substances, difference measurements, and versatile data-handling procedures, provided essential information about complex systems at relatively low cost.
KW - polar markers
KW - non-polar markers
KW - organic pollutants
KW - treatment evaluation strategy
KW - landfill leachate
U2 - 10.1080/03067310600929225
DO - 10.1080/03067310600929225
M3 - Article
SN - 1029-0397
VL - 87
SP - 1
EP - 15
JO - International Journal of Environmental Analytical Chemistry
JF - International Journal of Environmental Analytical Chemistry
IS - 1