Development and validation of a new automatic algorithm for quantification of left ventricular volumes and function in gated myocardial perfusion SPECT using cardiac magnetic resonance as reference standard.

Forskningsoutput: TidskriftsbidragArtikel i vetenskaplig tidskriftPeer review

14 Citeringar (SciVal)
173 Nedladdningar (Pure)

Sammanfattning

BACKGROUND: By gating image acquisition in myocardial perfusion SPECT (MPS) to ECG, left ventricular (LV) volumes and function can be determined. Several previous studies have shown that existing MPS software packages underestimate LV volumes compared to cardiac magnetic resonance (CMR). The aim of this study was therefore to develop a new LV segmentation algorithm for gated MPS using CMR as reference standard. METHODS AND RESULTS: A total of 126 patients with suspected coronary artery disease, who underwent both gated MPS and CMR were retrospectively included. The proposed LV segmentation algorithm (Segment) was trained in 26 patients, and tested in 100 patients in comparison to four commercially available MPS software packages (QGS, MyoMetrix, ECTb, and Exini) using CMR as reference standard. Mean bias ± SD between MPS and CMR was for EDV -5% ± 12%, -43% ± 8%, -40% ± 8%, -42% ± 9%, -32% ± 7%, for ESV 0% ± 17%, -41% ± 16%, -34% ± 15%, -54% ± 13%, -41% ± 10%, for EF -2% ± 13%, -1% ± 14%, -7% ± 15%, 17% ± 16%, 10% ± 17% for Segment, QGS, MyoMetrix, ECTb, and Exini, respectively, and for LVM 3% ± 18%, 33% ± 25%, 37% ± 24% for Segment, QGS, and ECTb, respectively. Correlation between MPS by Segment and CMR were for EDV R (2) = 0.89, for ESV R (2) = 0.92, for EF R (2) = 0.69, and for LVM R (2) = 0.72, with no difference compared to the correlation between the other MPS software packages and CMR (EDV R (2) = 0.86-0.92, ESV R (2) = 0.91-0.93, EF R (2) = 0.64-0.65, and LVM R (2) = 0.68-0.70). CONCLUSION: The Segment software quantifies LV volumes and EF by MPS with similar correlation and a low bias compared to other MPS software packages, using CMR as reference standard. Hence, the Segment software shows potential to provide clinically relevant volumes and functional values from MPS.
Originalspråkengelska
Sidor (från-till)874-885
TidskriftJournal of Nuclear Cardiology
Volym18
Utgåva5
DOI
StatusPublished - 2011

Bibliografisk information

The information about affiliations in this record was updated in December 2015.
The record was previously connected to the following departments: Department of Clinical Physiology (Lund) (013013000), Numerical Analysis (011015004)

Ämnesklassifikation (UKÄ)

  • Kardiologi

Fingeravtryck

Utforska forskningsämnen för ”Development and validation of a new automatic algorithm for quantification of left ventricular volumes and function in gated myocardial perfusion SPECT using cardiac magnetic resonance as reference standard.”. Tillsammans bildar de ett unikt fingeravtryck.

Citera det här