Sammanfattning
X-ray fluorescence microscopy performed at nanofocusing synchrotron beamlines produces quantitative elemental distribution maps at unprecedented resolution (down to a few tens of nanometres), at the expense of relatively long measuring times and high absorbed doses. In this work, a method was implemented in which fast low-dose in-line holography was used to produce quantitative electron density maps at the mesoscale prior to nanoscale X-ray fluorescence acquisition. These maps ensure more efficient fluorescence scans and the reduction of the total absorbed dose, often relevant for radiation-sensitive (e.g. biological) samples. This multimodal microscopy approach was demonstrated on human sural nerve tissue. The two imaging modes provide complementary information at a comparable resolution, ultimately limited by the focal spot size. The experimental setup presented allows the user to swap between them in a flexible and reproducible fashion, as well as to easily adapt the scanning parameters during an experiment to fine-tune resolution and field of view.
Originalspråk | engelska |
---|---|
Tidskrift | Journal of Synchrotron Radiation |
Volym | 29 |
Nummer | 3 |
DOI | |
Status | Published - 2022 mars 16 |
Ämnesklassifikation (UKÄ)
- Atom- och molekylfysik och optik (Här ingår: Kemisk fysik, kvantoptik)
- Radiologi och bildbehandling
- Subatomär fysik