T1 - Evaluating Laboratory Measurements for Sound Insulation of Cross-Laminated Timber (CLT) Floors
T2 - Configurations in Lightweight Buildings
AU - Vardaxis, Nikolaos Georgios
AU - Bard Hagberg, Delphine
AU - Dahlström, Jessica
PY - 2022
Y1 - 2022
N2 - Cross-laminated timber (CLT) floors with supplementary layers or floating floors comprise a common solution in new multistory timber structures. However, bare CLT components provide poor sound insulation, especially in low frequencies during structure-borne sound propagation. Thus, floor configurations in wooden buildings deploy more layers for improved acoustic behavior. Twelve contemporary CLT floors were analyzed after laboratory measurements of airborne sound reduction and impact sound transmission utilizing the following indicators: (Formula presented.), (Formula presented.), (Formula presented.), (Formula presented.), (Formula presented.), and (Formula presented.) (per ISO 10140, ISO 717). An increase in sound insulation was achieved thanks to added total mass and thickness, testing layers of the following: elastic mat for vibration isolation, wool insulation, gypsum boards, plywood, concrete screed, and wooden parquet floor. The results indicate that multilayered CLT floors can provide improvements of up to 22 dB for airborne sound and 32 dB for impact sound indicators compared with the bare CLT slab. Floating floor configurations with dry floor solutions (concrete screed) and wooden parquet floors stand out as the optimal cases. The parquet floor provides a 1–2 dB improvement only for impact sound indicators in floating floor setups (or higher in three cases).
AB - Cross-laminated timber (CLT) floors with supplementary layers or floating floors comprise a common solution in new multistory timber structures. However, bare CLT components provide poor sound insulation, especially in low frequencies during structure-borne sound propagation. Thus, floor configurations in wooden buildings deploy more layers for improved acoustic behavior. Twelve contemporary CLT floors were analyzed after laboratory measurements of airborne sound reduction and impact sound transmission utilizing the following indicators: (Formula presented.), (Formula presented.), (Formula presented.), (Formula presented.), (Formula presented.), and (Formula presented.) (per ISO 10140, ISO 717). An increase in sound insulation was achieved thanks to added total mass and thickness, testing layers of the following: elastic mat for vibration isolation, wool insulation, gypsum boards, plywood, concrete screed, and wooden parquet floor. The results indicate that multilayered CLT floors can provide improvements of up to 22 dB for airborne sound and 32 dB for impact sound indicators compared with the bare CLT slab. Floating floor configurations with dry floor solutions (concrete screed) and wooden parquet floors stand out as the optimal cases. The parquet floor provides a 1–2 dB improvement only for impact sound indicators in floating floor setups (or higher in three cases).
KW - airborne sound
KW - cross-laminated timber
KW - impact noise
KW - sound insulation
KW - timber
U2 - 10.3390/app12157642
DO - 10.3390/app12157642
M3 - Article
AN - SCOPUS:85136915754
VL - 12
JO - Applied Sciences (Switzerland)
JF - Applied Sciences (Switzerland)
SN - 2076-3417
IS - 15
M1 - 7642
ER -