TY - JOUR
T1 - Investigation and compensation of the nonlinear response in photomultiplier tubes for quantitative single-shot measurements.
AU - Knappe, Christoph
AU - Lindén, Johannes
AU - Abou Nada, Fahd Jouda
AU - Richter, Mattias
AU - Aldén, Marcus
PY - 2012
Y1 - 2012
N2 - A concept for time-sensitive optical detectors is described that shows how to confirm whether the detection device is operating in the linear response regime. By evaluating the recorded time decay of a thermographic phosphor, even weak saturation effects far from obvious situations can be identified and further related to either optical or electrical saturation. The concept has been validated by running a PMT detector close to saturation and exposing it to the optical signal decay of two different thermographic phosphors, La(2)O(2)S:Eu and CdWO(4). It was confirmed that short but intense light exposures at the beginning of an individual time decay influence the detector response for the rest of the decaying signal including temporal areas, where the anode current has dropped well below the manufacturer specified current limit. Such situations are common when applying, e.g., phosphor thermometry where it is necessary to retrieve the full decay curve from a single-shot event, i.e., standard techniques based on single-photon counting are omitted. Finally, means of compensation are introduced in order to facilitate the retrieval of useful information from the measurement data when operation in the non-linear response regime is inevitable.
AB - A concept for time-sensitive optical detectors is described that shows how to confirm whether the detection device is operating in the linear response regime. By evaluating the recorded time decay of a thermographic phosphor, even weak saturation effects far from obvious situations can be identified and further related to either optical or electrical saturation. The concept has been validated by running a PMT detector close to saturation and exposing it to the optical signal decay of two different thermographic phosphors, La(2)O(2)S:Eu and CdWO(4). It was confirmed that short but intense light exposures at the beginning of an individual time decay influence the detector response for the rest of the decaying signal including temporal areas, where the anode current has dropped well below the manufacturer specified current limit. Such situations are common when applying, e.g., phosphor thermometry where it is necessary to retrieve the full decay curve from a single-shot event, i.e., standard techniques based on single-photon counting are omitted. Finally, means of compensation are introduced in order to facilitate the retrieval of useful information from the measurement data when operation in the non-linear response regime is inevitable.
U2 - 10.1063/1.3693618
DO - 10.1063/1.3693618
M3 - Article
C2 - 22462946
VL - 83
JO - The Review of Scientific Instruments
JF - The Review of Scientific Instruments
SN - 1089-7623
IS - 3
M1 - 034901
ER -