TY - JOUR
T1 - Long-term safety and efficacy of drug-eluting and bare metal stents in saphenous vein grafts
AU - Frobert, Ole
AU - Scherstén, Fredrik
AU - James, Stefan K.
AU - Carlsson, Jorg
AU - Lagerqvist, Bo
PY - 2012
Y1 - 2012
N2 - Background Long-term safety and efficacy data of drug-eluting stents (DESs) in saphenous vein grafts (SVGs) are lacking. This study sought to compare the clinical outcomes of DES versus bare metal stents (BMS) in SVGs. Methods We studied all stent implantations in SVGs in Sweden during 74 months between 2005 and 2011 registered in the Swedish Coronary Angiography and Angioplasty Registry. We evaluated outcome in patients who received DES compared with those who received BMS after adjustments for differences in clinical, vessel, and lesion characteristics. Results Mean follow-up time was 3 years and 4 months. A total of 4,576 stents, implanted at 3,063 procedures, were included in the analysis of which 2,499 stents (54.6 %) were BMS and 2,077 (45.4%) were DES. The outcome analysis was based on 190 stent thromboses, 898 restenoses, and 523 deaths. The incidence of stent thrombosis did not differ between groups. When adjusted for baseline characteristics, including a propensity score for receiving DES, the incidence of restenosis was significantly lower with DES as compared with BMS (risk ratio 0.83, 95% CI 0.70-0.97, P = .019). There was a difference in mortality in the crude analysis between DES and BMS, and after multivariable adjustment, this difference remained statistically significant (risk ratio 0.80, CI 0.65-0.99, P = .038). Conclusions The use of DES compared with BMS in SVGs was associated with a significantly lower adjusted incidence of restenosis and death in this large, national, all-encompassing propensity adjusted observational study. (Am Heart J 2012;164:87-93.)
AB - Background Long-term safety and efficacy data of drug-eluting stents (DESs) in saphenous vein grafts (SVGs) are lacking. This study sought to compare the clinical outcomes of DES versus bare metal stents (BMS) in SVGs. Methods We studied all stent implantations in SVGs in Sweden during 74 months between 2005 and 2011 registered in the Swedish Coronary Angiography and Angioplasty Registry. We evaluated outcome in patients who received DES compared with those who received BMS after adjustments for differences in clinical, vessel, and lesion characteristics. Results Mean follow-up time was 3 years and 4 months. A total of 4,576 stents, implanted at 3,063 procedures, were included in the analysis of which 2,499 stents (54.6 %) were BMS and 2,077 (45.4%) were DES. The outcome analysis was based on 190 stent thromboses, 898 restenoses, and 523 deaths. The incidence of stent thrombosis did not differ between groups. When adjusted for baseline characteristics, including a propensity score for receiving DES, the incidence of restenosis was significantly lower with DES as compared with BMS (risk ratio 0.83, 95% CI 0.70-0.97, P = .019). There was a difference in mortality in the crude analysis between DES and BMS, and after multivariable adjustment, this difference remained statistically significant (risk ratio 0.80, CI 0.65-0.99, P = .038). Conclusions The use of DES compared with BMS in SVGs was associated with a significantly lower adjusted incidence of restenosis and death in this large, national, all-encompassing propensity adjusted observational study. (Am Heart J 2012;164:87-93.)
U2 - 10.1016/j.ahj.2012.04.012
DO - 10.1016/j.ahj.2012.04.012
M3 - Article
C2 - 22795287
SN - 1097-6744
VL - 164
SP - 87
EP - 93
JO - American Heart Journal
JF - American Heart Journal
IS - 1
ER -