MAX IV Photocathode Gun Laser System Specification and Diagnostics

F Lindau, J Andersson, J Björklund Svensson, M Brandin, F Curbis, M Kotur, D Kumbaro, E Mansten, L Isaksson, D Olsson, R Svärd, S Thorin, S Werin

Forskningsoutput: Kapitel i bok/rapport/Conference proceedingKonferenspaper i proceeding

3 Citeringar (SciVal)

Sammanfattning

The MAXIV injector has two guns - a thermionic used for ring injections, and a photocathode used for short pulse facility operation. A commercial Ti:sapphire laser from KMLabs drives the copper based photocathode gun. It has been running without major issues for more than 3 years. The laser delivers up to §I{500}{\textmu J} on the cathode at the third harmonic, §I{263}{nm}, via a vacuum laser transport system. To achieve the desired pulse duration of 2–§I10{ps} the laser pulses, originally ~§I{100}{fs} long, are stretched with a prism pair and the resulting §I{1.5}{ps} pulses stacked by a series of birefringent \textalpha -BBO crystals. Diagnostics consist of photodiodes, spectrometers, and cameras. Longitudinal pulse characterization is done with a cross correlator and a UV FROG.
Originalspråkengelska
Titel på värdpublikationIPAC 2017 - Proceedings of the 8th International Particle Accelerator Conference
UtgivningsortCopenhagen
FörlagJACoW Publishing
Sidor1544-1546
Antal sidor3
ISBN (elektroniskt)9783954501823
ISBN (tryckt)9783954501823
DOI
StatusPublished - 2017
Evenemang8th International Particle Accelerator Conference, IPAC 2017 - Bella Center, Bella Conference Center, Danmark
Varaktighet: 2017 maj 142017 maj 19

Konferens

Konferens8th International Particle Accelerator Conference, IPAC 2017
Land/TerritoriumDanmark
OrtBella Conference Center
Period2017/05/142017/05/19

Ämnesklassifikation (UKÄ)

  • Acceleratorfysik och instrumentering

Fingeravtryck

Utforska forskningsämnen för ”MAX IV Photocathode Gun Laser System Specification and Diagnostics”. Tillsammans bildar de ett unikt fingeravtryck.

Citera det här