TY - JOUR
T1 - Maximum detection distances for gamma emitting point sources in mobile gamma spectrometry
AU - Finck, Robert
AU - Bukartas, Antanas
AU - Jönsson, Mattias
AU - Rääf, Christopher
PY - 2022
Y1 - 2022
N2 - In this study an algorithm was developed for calculating maximum detectable distance (MDD) for mobile gamma-ray detection of lost sources in-situ for some common mobile spectrometer systems and gamma sources (137Cs and 60Co). The MDD is a function of detector efficiency, vehicle speed, acquisition time interval, radiation background level and accepted frequency of false alarms. To test its accuracy in predicting the MDD experiments were conducted in-situ. Results indicate agreement with experimental mobile detection distance measurements for 60Co and 137Cs point sources. Both the algorithm and the field test show that at a vehicle speed of 50 km/h, the optimal acquisition time intervals range between 3 and 10 s when searching for unshielded sources with activities of 137Cs and 60Co in the order of 100 MBq. Longer acquisition time intervals (20–30 s) are better to detect higher activity sources at the same speed. However, at higher speeds, shorter time intervals should be selected to increase the MDD. The developed algorithm can help select the optimal combination of detectors, vehicle speed, and instrument settings when using mobile searching in the event of loss of gamma-ray sources.
AB - In this study an algorithm was developed for calculating maximum detectable distance (MDD) for mobile gamma-ray detection of lost sources in-situ for some common mobile spectrometer systems and gamma sources (137Cs and 60Co). The MDD is a function of detector efficiency, vehicle speed, acquisition time interval, radiation background level and accepted frequency of false alarms. To test its accuracy in predicting the MDD experiments were conducted in-situ. Results indicate agreement with experimental mobile detection distance measurements for 60Co and 137Cs point sources. Both the algorithm and the field test show that at a vehicle speed of 50 km/h, the optimal acquisition time intervals range between 3 and 10 s when searching for unshielded sources with activities of 137Cs and 60Co in the order of 100 MBq. Longer acquisition time intervals (20–30 s) are better to detect higher activity sources at the same speed. However, at higher speeds, shorter time intervals should be selected to increase the MDD. The developed algorithm can help select the optimal combination of detectors, vehicle speed, and instrument settings when using mobile searching in the event of loss of gamma-ray sources.
KW - Detection distance
KW - Mobile gamma spectrometry
KW - Orphan source search
U2 - 10.1016/j.apradiso.2022.110195
DO - 10.1016/j.apradiso.2022.110195
M3 - Article
C2 - 35338972
AN - SCOPUS:85126972670
SN - 0969-8043
VL - 184
JO - Applied Radiation and Isotopes
JF - Applied Radiation and Isotopes
M1 - 110195
ER -