Återgå till huvudnavigering Återgå till sök Gå direkt till huvudinnehållet

Measurements of sensor radiation damage in the ATLAS inner detector using leakage currents

  • Aix-Marseille University
  • CERN

Forskningsoutput: Tidskriftsbidrag › Artikel i vetenskaplig tidskrift › Peer review

Sammanfattning

Non-ionizing energy loss causes bulk damage to the silicon sensors of the ATLAS pixel and strip detectors. This damage has important implications for data-taking operations, charged-particle track reconstruction, detector simulations, and physics analysis. This paper presents simulations and measurements of the leakage current in the ATLAS pixel detector and semiconductor tracker as a function of location in the detector and time, using data collected in Run 1 (2010–2012) and Run 2 (2015–2018) of the Large Hadron Collider. The extracted fluence shows a much stronger |z|-dependence in the innermost layers than is seen in simulation. Furthermore, the overall fluence on the second innermost layer is significantly higher than in simulation, with better agreement in layers at higher radii. These measurements are important for validating the simulation models and can be used in part to justify safety factors for future detector designs and interventions.
Originalspråkengelska
ArtikelnummerP08025
TidskriftJournal of Instrumentation
Volym16
Nummer8
DOI
StatusPublished - 2021

Ämnesklassifikation (UKÄ)

  • Subatomär fysik

Fingeravtryck

Utforska forskningsämnen för ”Measurements of sensor radiation damage in the ATLAS inner detector using leakage currents”. Tillsammans bildar de ett unikt fingeravtryck.

Citera det här