TY - JOUR
T1 - Optimization of Aeration Diffuser System Design
T2 - A Simulation Study
AU - Bengtsson, Simon
AU - Arnell, Magnus
PY - 2023/4
Y1 - 2023/4
N2 - The influence of aeration diffuser system design on electricity usage, effluent water quality, and life-cycle cost in biological wastewater treatment was investigated. A plant-wide model was implemented, and simulations were carried out with different process configurations and aeration systems. Model-aided design of new aeration diffuser systems could significantly decrease electricity usage and life-cycle cost while at the same time avoiding negative effects on the treatment performance. The optimum distribution of diffuser systems in tanks in series was found to be influenced by process configuration, volumetric loading rate, temperature, and the internal recirculation flow rate. Compared with a conventional design approach, increasing the number of diffusers, up to a critical point, led to higher energy efficiency and lower life-cycle cost. This was despite an increasing limitation of the minimum airflow rate, leading to dissolved oxygen levels significantly exceeding control targets. Aeration systems optimized by simulations were found to, independently of process configuration, exhibit 20% lower electricity usage and 16%-18% lower life-cycle costs compared with systems designed based on a more conventional approach typically applied in practice.
AB - The influence of aeration diffuser system design on electricity usage, effluent water quality, and life-cycle cost in biological wastewater treatment was investigated. A plant-wide model was implemented, and simulations were carried out with different process configurations and aeration systems. Model-aided design of new aeration diffuser systems could significantly decrease electricity usage and life-cycle cost while at the same time avoiding negative effects on the treatment performance. The optimum distribution of diffuser systems in tanks in series was found to be influenced by process configuration, volumetric loading rate, temperature, and the internal recirculation flow rate. Compared with a conventional design approach, increasing the number of diffusers, up to a critical point, led to higher energy efficiency and lower life-cycle cost. This was despite an increasing limitation of the minimum airflow rate, leading to dissolved oxygen levels significantly exceeding control targets. Aeration systems optimized by simulations were found to, independently of process configuration, exhibit 20% lower electricity usage and 16%-18% lower life-cycle costs compared with systems designed based on a more conventional approach typically applied in practice.
KW - Activated sludge
KW - Aeration efficiency
KW - Benchmark simulation model
KW - Diffuser system design
KW - Energy
U2 - 10.1061/JOEEDU.EEENG-7047
DO - 10.1061/JOEEDU.EEENG-7047
M3 - Article
AN - SCOPUS:85146938760
SN - 0733-9372
VL - 149
JO - Journal of Environmental Engineering (United States)
JF - Journal of Environmental Engineering (United States)
IS - 4
M1 - 04023003
ER -