T1 - Phase-based arterial input functions in humans applied to dynamic contrast-enhanced MRI: potential usefulness and limitations
AU - Garpebring, Anders
AU - Wirestam, Ronnie
AU - Yu, Jun
AU - Asklund, Thomas
AU - Karlsson, Mikael
PY - 2011
Y1 - 2011
N2 - Object Phase-based arterial input functions (AIFs) provide a promising alternative to standard magnitude-based AIFs, for example, because inflow effects are avoided. The usefulness of phase-based AIFs in clinical dynamic contrast-enhanced MRI (DCE-MRI) was investigated, and relevant pitfalls and sources of uncertainty were identified. Materials and methods AIFs were registered from eight human subjects on, in total, 21 occasions. AIF quality was evaluated by comparing AIFs from right and left internal carotid arteries and by assessing the reliability of blood plasma volume estimates. Results Phase-based AIFs yielded an average bolus peak of 3.9 mM and a residual concentration of 0.37 mM after 3 min, (0.033 mmol/kg contrast agent injection). The average blood plasma volume was 2.7% when using the AIF peak in the estimation, but was significantly different (p < 0.0001) and less physiologically reasonable when based on the AIF tail concentration. Motion-induced phase shifts and accumulation of contrast agent in background tissue regions were identified as main sources of uncertainty. Conclusion Phase-based AIFs are a feasible alternative to magnitude AIFs, but sources of errors exist, making quantification difficult, especially of the AIF tail. Improvement of the technique is feasible and also required for the phase-based AIF approach to reach its full potential.
AB - Object Phase-based arterial input functions (AIFs) provide a promising alternative to standard magnitude-based AIFs, for example, because inflow effects are avoided. The usefulness of phase-based AIFs in clinical dynamic contrast-enhanced MRI (DCE-MRI) was investigated, and relevant pitfalls and sources of uncertainty were identified. Materials and methods AIFs were registered from eight human subjects on, in total, 21 occasions. AIF quality was evaluated by comparing AIFs from right and left internal carotid arteries and by assessing the reliability of blood plasma volume estimates. Results Phase-based AIFs yielded an average bolus peak of 3.9 mM and a residual concentration of 0.37 mM after 3 min, (0.033 mmol/kg contrast agent injection). The average blood plasma volume was 2.7% when using the AIF peak in the estimation, but was significantly different (p < 0.0001) and less physiologically reasonable when based on the AIF tail concentration. Motion-induced phase shifts and accumulation of contrast agent in background tissue regions were identified as main sources of uncertainty. Conclusion Phase-based AIFs are a feasible alternative to magnitude AIFs, but sources of errors exist, making quantification difficult, especially of the AIF tail. Improvement of the technique is feasible and also required for the phase-based AIF approach to reach its full potential.
KW - Dynamic contrast-enhanced MRI
KW - Arterial input function
KW - Phase
KW - quantification
UR - https://www.scopus.com/pages/publications/80052467041
U2 - 10.1007/s10334-011-0257-8
DO - 10.1007/s10334-011-0257-8
M3 - Article
C2 - 21626278
SN - 1352-8661
VL - 24
SP - 233
EP - 245
JO - Magma
JF - Magma
IS - 4
ER -