N2 - In this work, two pharmacokinetic modeling techniques, population arterial input function model, and reference region model, were applied to dynamic contract-enhanced MRI data, to test the influence of a change in heart rate on modeling parameters. A rat population arterial input function was generated by dynamic contrast-enhanced computed tomography measurements using the MR contrast agent gadolinium diethylenetriamine penta-acetic acid. Then, dynamic contract-enhanced MRI was used for treatment monitoring in two groups of hepatocellular carcinoma bearing rats. Whereas group 1 had the same heart rate as animals analyzed for the population arterial input function (263 +/- 20 bpm), group 2 had a higher heart rate (369 +/- 11 bpm) due to a different anesthesia protocol. The pharmacokinetic modeling parameters volume transfer constant K-trans and relative extravascular extracellular space v(e) were calculated with both models and statistically compared. For group 1, good correlation and agreement was found between the models showing no difference in K-trans and v(e) (Delta K-trans:4 +/- 19% and Delta v(e):4 +/- 12%, P = 0.2). In contrast, for group 2, a bias in parameter values for the population arterial input function model was detected (Delta K-trans: -45 +/- 7% and Delta v(e):-31 +/- 7%, P <= 0.001). The presented work underlines the value of the reference region model in longitudinal treatment monitoring and provides a straightforward approach for the generation of a rat population arterial input function. Magn Reson Med 65: 229-238, 2011. (C) 2010 Wiley-Liss, Inc.
AB - In this work, two pharmacokinetic modeling techniques, population arterial input function model, and reference region model, were applied to dynamic contract-enhanced MRI data, to test the influence of a change in heart rate on modeling parameters. A rat population arterial input function was generated by dynamic contrast-enhanced computed tomography measurements using the MR contrast agent gadolinium diethylenetriamine penta-acetic acid. Then, dynamic contract-enhanced MRI was used for treatment monitoring in two groups of hepatocellular carcinoma bearing rats. Whereas group 1 had the same heart rate as animals analyzed for the population arterial input function (263 +/- 20 bpm), group 2 had a higher heart rate (369 +/- 11 bpm) due to a different anesthesia protocol. The pharmacokinetic modeling parameters volume transfer constant K-trans and relative extravascular extracellular space v(e) were calculated with both models and statistically compared. For group 1, good correlation and agreement was found between the models showing no difference in K-trans and v(e) (Delta K-trans:4 +/- 19% and Delta v(e):4 +/- 12%, P = 0.2). In contrast, for group 2, a bias in parameter values for the population arterial input function model was detected (Delta K-trans: -45 +/- 7% and Delta v(e):-31 +/- 7%, P <= 0.001). The presented work underlines the value of the reference region model in longitudinal treatment monitoring and provides a straightforward approach for the generation of a rat population arterial input function. Magn Reson Med 65: 229-238, 2011. (C) 2010 Wiley-Liss, Inc.
KW - quantitative dynamic contract-enhanced MRI
KW - population arterial input
KW - function
KW - reference region model
KW - hepatocellular carcinoma rat tumor
KW - model
U2 - 10.1002/mrm.22589
DO - 10.1002/mrm.22589
M3 - Article
VL - 65
SP - 229
EP - 238
JO - Magnetic Resonance in Medicine
JF - Magnetic Resonance in Medicine
SN - 1522-2594
IS - 1
ER -