Shape determination of microcalcifications in simulated digital mammography images with varying pixel size

Mark Ruschin, M Bath, Bengt Hemdal, Anders Tingberg

Forskningsoutput: Kapitel i bok/rapport/Conference proceedingKonferenspaper i proceedingPeer review

Sammanfattning

The purpose of this work was to study how the pixel size of digital detectors can affect shape determination of microcalcifications in mammography. Screen-film mammograms containing microcalcifications clinically proven to be indicative of malignancy were digitised at 100 lines/mm using a high-resolution Tango drum scanner. Forty microcalcifications were selected to cover an appropriate range of sizes, shapes and contrasts typically found of malignant cases. Based on the measured MTF and NPS of the combined screen-film and scanner system, these digitised images were filtered to simulate images acquired with a square sampling pixel size of 10 μm × 10 μm and a fill factor of one. To simulate images acquired with larger pixel sizes, these finely sampled images were re-binned to yield a range of effective pixel sizes from 20 μm up to 140 μm. An alternative forced-choice (AFC) observer experiment was conducted with eleven observers for this set of digitised microcalcifications to determine how pixel size affects the ability to discriminate shape. It was found that observer score increased with decreasing pixel size down to 60 μm (p<0.01), at which point no significant advantage was obtained by using smaller pixel sizes due to the excessive relative noise-per-pixel. The relative gain in shape discrimination ability at smaller pixel sizes was larger for microcalcifications that were smaller than 500 μm and circular
Originalspråkengelska
Titel på värdpublikationProceedings of the SPIE - The International Society for Optical Engineering
FörlagSPIE
Sidor288-299
Volym5749
DOI
StatusPublished - 2005
EvenemangMedical Imaging 2005: Image Perception, Observer Performance, and Technology Assessment - San Diego, CA, USA
Varaktighet: 2005 feb. 15 → …

Publikationsserier

Namn
Nummer1
Volym5749
ISSN (tryckt)1996-756X
ISSN (elektroniskt)0277-786X

Konferens

KonferensMedical Imaging 2005: Image Perception, Observer Performance, and Technology Assessment
Land/TerritoriumUSA
OrtSan Diego, CA
Period2005/02/15 → …

Ämnesklassifikation (UKÄ)

  • Radiologi och bildbehandling

Fingeravtryck

Utforska forskningsämnen för ”Shape determination of microcalcifications in simulated digital mammography images with varying pixel size”. Tillsammans bildar de ett unikt fingeravtryck.

Citera det här