TY - JOUR
T1 - Super-Resolution Cine Image Enhancement for Fetal Cardiac Magnetic Resonance Imaging
AU - Berggren, Klas
AU - Ryd, Daniel
AU - Heiberg, Einar
AU - Aletras, Anthony
AU - Hedström, Erik
PY - 2022
Y1 - 2022
N2 - BackgroundFetal cardiac magnetic resonance imaging (MRI) improves the diagnosis of congenital heart defects, but is sensitive to fetal motion due to long image acquisition time. This may be overcome with faster image acquisition with low resolution, followed by image enhancement to provide clinically useful images.PurposeTo combine phase-encoding undersampling with super-resolution neural networks to achieve high-resolution fetal cine cardiac MR images with short acquisition time.Study TypeProspective.SubjectsTwenty-eight fetuses (gestational week 36 [interquartile range 33–38 weeks]).Field Strength/Sequence1.5 T, balanced steady-state free precession (bSSFP) cine sequence.AssessmentImages were acquired using fully sampled Doppler ultrasound-gated clinical bSSFP cine as reference, with equivalent cine sequences with decreased phase-encoding resolution (25%, 33%, and 50% of clinical standard). Two super-resolution methods based on convolutional neural networks were proposed and evaluated (phasrGAN and phasrresnet). Data were partitioned into training (36 cine slices), validation (3 cine slices), and test sets (67 cine slices) without overlap. Conventional reconstruction methods using bicubic interpolation and k-space zeropadding were used for comparison. Three blinded observers scored image quality between 1 and 10.Statistical TestsImage scores are reported as median [interquartile range] and were compared using Mann–Whitney's nonparametric test with P < 0.05 showing statistically significant differences.ResultsBoth proposed methods showed no significant difference in image quality compared to clinical images (8 [7–8.5]) down to 33% (phasrGAN 8 [6.5–8]; phasrresnet 8 [7–8], all P ≥ 0.19) phase-encoding resolution, i.e., up to three times faster image acquisition, whereas bicubic interpolation and k-space zeropadding showed significantly lower quality for 33% phase-encoding resolution (both 7 [6–8]).Data ConclusionSuper-resolution enhancement can be used for fetal cine cardiac MRI to reduce image acquisition time while maintaining image quality. This may lead to an improved success rate for fetal cine MR imaging, as the impact of fetal motion is lessened by shortened acquisitions.Level of Evidence1Technical EfficacyStage 2
AB - BackgroundFetal cardiac magnetic resonance imaging (MRI) improves the diagnosis of congenital heart defects, but is sensitive to fetal motion due to long image acquisition time. This may be overcome with faster image acquisition with low resolution, followed by image enhancement to provide clinically useful images.PurposeTo combine phase-encoding undersampling with super-resolution neural networks to achieve high-resolution fetal cine cardiac MR images with short acquisition time.Study TypeProspective.SubjectsTwenty-eight fetuses (gestational week 36 [interquartile range 33–38 weeks]).Field Strength/Sequence1.5 T, balanced steady-state free precession (bSSFP) cine sequence.AssessmentImages were acquired using fully sampled Doppler ultrasound-gated clinical bSSFP cine as reference, with equivalent cine sequences with decreased phase-encoding resolution (25%, 33%, and 50% of clinical standard). Two super-resolution methods based on convolutional neural networks were proposed and evaluated (phasrGAN and phasrresnet). Data were partitioned into training (36 cine slices), validation (3 cine slices), and test sets (67 cine slices) without overlap. Conventional reconstruction methods using bicubic interpolation and k-space zeropadding were used for comparison. Three blinded observers scored image quality between 1 and 10.Statistical TestsImage scores are reported as median [interquartile range] and were compared using Mann–Whitney's nonparametric test with P < 0.05 showing statistically significant differences.ResultsBoth proposed methods showed no significant difference in image quality compared to clinical images (8 [7–8.5]) down to 33% (phasrGAN 8 [6.5–8]; phasrresnet 8 [7–8], all P ≥ 0.19) phase-encoding resolution, i.e., up to three times faster image acquisition, whereas bicubic interpolation and k-space zeropadding showed significantly lower quality for 33% phase-encoding resolution (both 7 [6–8]).Data ConclusionSuper-resolution enhancement can be used for fetal cine cardiac MRI to reduce image acquisition time while maintaining image quality. This may lead to an improved success rate for fetal cine MR imaging, as the impact of fetal motion is lessened by shortened acquisitions.Level of Evidence1Technical EfficacyStage 2
U2 - 10.1002/jmri.27956
DO - 10.1002/jmri.27956
M3 - Article
C2 - 34652860
SN - 1522-2586
VL - 56
SP - 223
EP - 231
JO - Journal of Magnetic Resonance Imaging
JF - Journal of Magnetic Resonance Imaging
IS - 1
ER -