Thermal properties on high fill factor electrical windings: Infiltrated vs non infiltarted

Leif Siesing, Avo Reinap, Mats Andersson

Forskningsoutput: Kapitel i bok/rapport/Conference proceedingKonferenspaper i proceedingPeer review

3150 Nedladdningar (Pure)

Sammanfattning

This paper presents a comparison of the
thermal properties between infiltrated and non-infiltrated
copper windings. The focus is on thermal conductivity in the
radial direction on the winding. The samples have a fill factor
above 65 % due to the manufacturing method of the samples.
Samples are produced and measured with the transient plane
source technique and then compared to FEM simulations and
the Hashin and Shtrikman approximation. The results show a
considerable difference between a non-infiltrated and an
infiltrated winding, as well as a good agreement between
measurements, FEM simulations and the Hashin and
Shtrikman approximation
Originalspråkengelska
Titel på värdpublikation2014 International Conference on Electrical Machines (ICEM)
FörlagIEEE - Institute of Electrical and Electronics Engineers Inc.
Sidor2218-2223
Antal sidor6
ISBN (tryckt)9781479943883
DOI
StatusPublished - 2014
EvenemangInternational Conference on Electrical Machines (ICEM), 2014 - Berlin, Berlin, Tyskland
Varaktighet: 2014 sep. 22014 sep. 5

Konferens

KonferensInternational Conference on Electrical Machines (ICEM), 2014
Land/TerritoriumTyskland
OrtBerlin
Period2014/09/022014/09/05