Sammanfattning
An experimental technique based on double planar laser-induced fluorescence (PLIF/PLIF) using two tracers for the measurement of the local concentration of liquid phase in a two-phase system with large bubbles is presented. Fluorescence emission intensity calibration was performed to validate the use of the laser and tracer combinations at each point in the images on two CCD cameras, separately. By normalizing the fluorescence emission intensity of the first tracer with a known concentration, with the fluorescence emission of the second tracer, the optical problems related to the bubbly two-phase flow were minimized. Concentrations measured in a bubbly system are shown to be in good agreement with the true concentration values
| Originalspråk | engelska |
|---|---|
| Titel på värdpublikation | Advances in Fluid Mechanics. AFM 2002. Fourth International Conference |
| Förlag | WIT Press |
| Sidor | 427-437 |
| ISBN (tryckt) | 1-85312-910-0 |
| Status | Published - 2002 |
| Evenemang | 4th International Conference on Advances in Fluid Mechanics - Ghent, Belgien Varaktighet: 2002 maj 15 → 2002 maj 17 |
Konferens
| Konferens | 4th International Conference on Advances in Fluid Mechanics |
|---|---|
| Land/Territorium | Belgien |
| Ort | Ghent |
| Period | 2002/05/15 → 2002/05/17 |
Ämnesklassifikation (UKÄ)
- Annan teknik